<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-17 07-33-03
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
100.20 MHz 4/5, 36 dBuV INTER
Pilot RDS Phase Difference
7.2 kHz 2.8 kHz -50 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
20 kHz 25 kHz 4804 0,0416
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
1,2 dBr 2,67 dBr 4,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" INTER " F201 0 (No PTY) 1 0 1 1 7:33, 17.06.2024
RT
"LE JOURNAL DE 7H30 - JOURNAL 07H30 DU LUNDI 17 JUIN 2024 "
AF EON
92.6, 94.6, 94.9, 99.2, 99.9, 100.2 MHz F203, F209, F222, F202
FM Scope Station: 100.20 MHz, signal: 4/5 (36 dBuV) Max at: 25 kHz MIN: 20 kHz % above 75 kHz: 0,0416 Acquired: 2024/06/17 7:31:58 Total samples: 4804 Equivalent time: 0:04:00 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 50 100 150
FM Scope MAX: 4,7 dBr MIN: 1,2 dBr AVE: 2,67 dBr % above 11,2 dBr: 0,0 Last value: 3,1 dBr (2024/06/17 7:31:57) Station: 100.20 MHz, signal: 3/5 (36 dBuV) 07:20 07:22 07:24 07:26 07:28 07:30 0 50 100 Dev. MAX [kHz] 0 2 4 Pm [dBr] 0 5 Signal Quality